K5B - 8
5.0 Automatic Operation
Continuing: Preset Functions
Select function "Preset functions":
Scan Reference Positionj
In the case of a machine malfunction the reference point can be newly
scanned with this function.
Procedure:
1. Select "Scan reference position" < display change >
2. Confirm "Clear table surface" < display change >
3. Start backgauge run: Actuate electronical handweel in forward or
reverse operation
Abortion of reference run:
Press key
As soon as the reference run has been terminated, the menu "Correct. current
position" is displayed.
The displayed basic measurement must be confirmed (see page K5B - 7).
After this procedure the Program Data display will automatically be indicated.
Auxiliary operation
If no reference point is found during the reference run an auxiliary mode must
be activated (see page K7 - 3)
Possible funtions in Auxiliary mode:
cutting
manual displacement of backgauge by means of of electronic handwheel